380Cast-in-placeElectrical and plumbing

Cast-in-Place Loop

Cast-in-place hanger loop for utilities below steel deck: the 1-1/2 in. OD loop rests within the lower flute of the B-deck and casts into the pour.

Give us the size, drop and service and we’ll spec the part number and quote the build.

In use

In use.

Rated capacity

300 lbs
Support rated load, listed per ICC-ES PMG-1840 Table 1
3 - 120 in.
Length.
ICC-ES PMG mark of conformityQR code linking to ICC-ES PMG listing PMG-1840ICC-ES Evaluated
PMG-1840

Support rated load 300 lbs, listed per ICC-ES PMG-1840 (September 2026). The support hangs from its cast-in 1-1/2 in. OD loop resting in the lower flute of the steel deck; no separate fastener is required.

Custom order

Specify the size

Custom made per order.

Cast-in-Place Loop with callouts

Length, in.

Part number380A__Finish the selections to complete the request.

03 · Notes

From the Technical Data Sheet

  • Cast-in-place hanger loop for utilities below steel deck: the 1-1/2 in. OD loop rests within the lower flute of the B-deck and casts into the pour.
  • Dry locations only, per the listing.
  • Rated load carries a minimum 4:1 factor of safety on ultimate tested capacity per ICC-ES LC1041 and UL 2239.
  • Capacity applies with or without a concrete-filled deck.
  • The 1-1/2 in. OD loop remains within the lower flute, clear of the insulation.
  • Galvanized rod; corrosion resistant.
  • Electrical and plumbing: hangs conduit, MC/AC cable and piping below the deck.
  • Support spacing per NEC 330.30 (MC) and 358.30 (EMT), IPC Table 308.5 / UPC Table 313.3 (PEX) and IMC Table 305.4 (copper).
  • Drawings not to scale.

Send the spec. We’ll build the support.

Size, drop, and service. We’ll spec the part number and quote the build.